AONENG POWER

Products / Battery Energy Storage

Store energy.
Control when you use it.

AONENG battery energy storage systems combine LFP batteries, self-developed BMS and EMS, thermal management and multi-layer protection for commercial, industrial and larger energy applications.

Choose a platform

125kWRated power
261kWhNominal capacity
> 6,000Cycle life at 0.5C
IP54 / 55Protection rating
AN-ESS-125kW261kWh-LFP-YIntelligent liquid coolingAONENG battery energy storage cabinet980 × 1370 × 2330 mm< 2,600 kg

What storage does on site

Generation varies. Demand moves.
The grid has limits.

Choose an application to see how the battery charges and discharges across a typical day.

Peak shaving & valley filling

Illustrative 24-hour profile

The battery charges overnight, when demand and tariffs are low, and discharges when site demand approaches the contracted grid limit, so the grid sees a flatter profile.

GRID OUTAGECONTRACTED GRID LIMIT00:0006:0012:0018:0024:00kW
  • Site demand
  • Power drawn from the grid
  • Battery discharges
  • Battery charges off-peak

Illustration only — not measured site data. Sizing and dispatch are modelled for your load profile.

Industrial & logistics solutions →

Power and energy

kW is how fast.
kWh is how much.

Rated power limits the load a platform can carry. Capacity sets how long it can carry it. Pick a platform and a load to see both.

Platform

Constant load to support

Rated power125 kW

The largest load the PCS can supply or absorb.

Nominal capacity261 kWh

The energy stored when the system is full.

261 kWh at 50 kW

≈ 5.2 h

At a constant 50 kW, 261 kWh of nominal capacity lasts about 5.2 hours. The load is within the 125 kW rated power.

0 h3 h6 h9 h12 h

Simple arithmetic on nominal values: hours ≈ nominal capacity ÷ constant load. Usable energy depends on depth of discharge, conversion losses, temperature and ageing — our engineering team models these in the storage study.

From cell to grid

Thousands of cells. One control hierarchy.

PCS, BMS and EMS are developed in-house, so power conversion, battery management and dispatch are designed as one system.

EMS control layerForecast · optimise · dispatch · protect
Cell314 Ah LFP
Pack52.24 kWh
Cluster680–950 Vdc
Battery stack261 kWh
DC bus0.5C
PCSSelf-developed
Transformer/ switchgear
Grid / loadTHD ≤ 3%
BMU · cell and pack visibility
BCU · cluster control
BAU · system coordination

BMS · three-layer control across cell, pack, cluster and stack. Values shown for the 125 kW / 261 kWh platform.

Safety architecture

Detect early. Respond locally. Suppress automatically.

Safety engineered from cell level to site level, with pack-level targeted fire protection.

Cell→Pack→Cluster→System→Site
01PreventThermal management keeps cells inside their operating window.
02DetectThe BMS monitors cell, pack and cluster continuously.
03LocaliseFaults are isolated at the lowest level that contains them.
04SuppressPack-level targeted fire protection acts automatically.
05Alert & controlEMS and cloud alarms reach the operator in real time.
Three platforms · one storage family

Compare specifications

Storage brochure (PDF)
Platform60 kW / 101 kWhAN-ESS-60kW101kWh-LFPL100 kW / 215 kWhAN-ESS-100kW215kWh-LFP/F125 kW / 261 kWhAN-ESS-125kW261kWh-LFP-Y · flagship
CellLFP 3.2 V / 120 AhLFP 3.2 V / 280 AhLFP 3.2 V / 314 Ah
Battery pack9.216 kWh14.336 kWh52.24 kWh
DC voltage range680–1000 Vdc680–900 Vdc680–950 Vdc
Charge / discharge rate0.5C0.5C0.5C
Cycle lifeOn request> 6,000 at 25 °C / 0.5C> 6,000 at 0.5C
CoolingForced airSmart airIntelligent liquid
Protection ratingIP54IP54IP54 / IP55 (electrical / battery)
Ambient temperature−20 to +50 °C−20 to +50 °C−15 to +45 °C
Grid · THD380 Vac · ≤ 3%380 Vac · ≤ 3%380 Vac · ≤ 3%
Dimensions (W × D × H)1330 × 1090 × 2000 mm1600 × 1100 × 2300 mm980 × 1370 × 2330 mm
Weight< 1,500 kg< 2,600 kg< 2,600 kg

All platforms: humidity 0–95% RH, altitude ≤ 3,000 m, self-developed BMS and EMS with cloud O&M.

Scalable by design

Start with a cabinet. Scale into infrastructure.

One technology stack across deployment scales — without rebuilding the core energy architecture.

125 kWSingle cabinet · 261 kWh
500 kWCommercial · 1–2 MWh
2 MWIndustrial · 4–8 MWh
5 MWMicrogrid / campus · 10–20 MWh
10 MWGrid / renewable · 20–40 MWh+

Distributed cabinets → prefabricated systems → containerised BESS → utility plant

Proven in service

From storage pilots to integrated energy sites.

All storage projects
Ladepark AM charging park, GermanyGermany · Ladepark AMCharging-storage integration360 kW DC · 180 kW DC · 22 kW AC with storage
China · TonglingIntegrated solar-storage-charging pilot600kWCharging cluster7Liquid-cooled terminals215kWhStorage
China · State Grid SichuanDistributed storage for the grid operator60kWRated power101kWhCapacity
Delivery & contracting

Our scope goes as far as the project needs.

BESS supplyEquipment at the battery limit.
Supply + commissioningFactory engineers commission on site.
Turnkey deliveryIncluding civils and installation.
FAQ

Storage questions

Capacities, chemistry, safety and integration.

What battery chemistry does AONENG use in these BESS systems?

The approved portfolio uses LFP chemistry for the current commercial energy-storage configurations.

What sizes are available?

The range covers 101 kWh, 215 kWh and 261 kWh distributed systems, with the wider portfolio scaling to multi-MWh applications.

Is liquid cooling available?

Yes. The 261 kWh configuration uses intelligent liquid cooling; other models use different cooling architectures.

Can BESS support EV charging?

Yes. Storage can be integrated with EV charging to support peak demand, renewable energy use and site power management.

Do all BESS products have the same operating temperature and IP rating?

No. These specifications vary by model and must be taken from the exact approved datasheet.

Start a project

Store intelligently. Operate efficiently. Scale with confidence.

From a single charging site to a fleet depot, energy-storage system or high-power charging network, our team can help define the right solution.